CVE-2025-6887
- EPSS 0.35%
- Veröffentlicht 30.06.2025 04:32:29
- Zuletzt bearbeitet 01.07.2025 16:42:48
A vulnerability was found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this issue is some unknown functionality of the file /goform/SetSysTimeCfg. The manipulation of the argument time/timeZone leads to stack-based buffer overflow...
CVE-2025-6886
- EPSS 0.35%
- Veröffentlicht 30.06.2025 04:02:23
- Zuletzt bearbeitet 01.07.2025 16:47:02
A vulnerability has been found in Tenda AC5 15.03.06.47 and classified as critical. Affected by this vulnerability is an unknown functionality of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTime leads to st...
CVE-2025-5863
- EPSS 0.27%
- Veröffentlicht 09.06.2025 05:31:07
- Zuletzt bearbeitet 09.06.2025 19:02:45
A vulnerability was found in Tenda AC5 15.03.06.47. It has been classified as critical. Affected is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. ...
- EPSS 0.52%
- Veröffentlicht 06.06.2025 18:31:11
- Zuletzt bearbeitet 09.06.2025 19:08:11
A vulnerability, which was classified as critical, was found in Tenda AC5 1.0/15.03.06.47. This affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. It is possible to...
- EPSS 0.52%
- Veröffentlicht 06.06.2025 18:31:07
- Zuletzt bearbeitet 09.06.2025 19:08:21
A vulnerability, which was classified as critical, has been found in Tenda AC5 15.03.06.47. Affected by this issue is the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow...
CVE-2023-41563
- EPSS 0.12%
- Veröffentlicht 30.08.2023 13:15:15
- Zuletzt bearbeitet 21.11.2024 08:21:18
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter mac at url /goform/GetParentControlInfo.
CVE-2023-41559
- EPSS 0.16%
- Veröffentlicht 30.08.2023 13:15:14
- Zuletzt bearbeitet 21.11.2024 08:21:17
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.
CVE-2023-41557
- EPSS 0.12%
- Veröffentlicht 30.08.2023 13:15:14
- Zuletzt bearbeitet 21.11.2024 08:21:17
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat.
CVE-2023-41561
- EPSS 0.12%
- Veröffentlicht 30.08.2023 13:15:14
- Zuletzt bearbeitet 21.11.2024 08:21:18
Tenda AC9 V3.0 V15.03.06.42_multi and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter startIp and endIp at url /goform/SetPptpServerCfg.
CVE-2023-41562
- EPSS 0.12%
- Veröffentlicht 30.08.2023 13:15:14
- Zuletzt bearbeitet 21.11.2024 08:21:18
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.