6.5
CVE-2015-2746
- EPSS 25.58%
- Veröffentlicht 26.03.2015 14:59:03
- Zuletzt bearbeitet 06.05.2026 22:30:45
- Quelle cve@mitre.org
- CVE-Watchlists
- Unerledigt
The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Websense ≫ V-series Appliances Version <= 7.7
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 25.58% | 0.977 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 6.5 | 8 | 6.4 |
AV:N/AC:L/Au:S/C:P/I:P/A:P
|
CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
http://packetstormsecurity.com/files/130899/Websense-Appliance-Manager-Command-Injection.html
http://seclists.org/fulldisclosure/2015/Mar/104
http://www.securityfocus.com/archive/1/534910/100/0/threaded
http://www.websense.com/support/article/kbarticle/October-2014-Hotfix-Summary-for-Websense-Solutions
https://www.exploit-db.com/exploits/36423/
https://www.securify.nl/advisory/SFY20140906/command_injection_vulnerability_in_network_diagnostics_tool_of_websense_appliance_manager.html