9.3

CVE-2007-6189

A certain ActiveX control in (1) OScan8.ocx and (2) Oscan81.ocx in BitDefender Online Anti-Virus Scanner 8.0 allows remote attackers to execute arbitrary code via a long argument to the InitX method that begins with a "%%" sequence, which is misinterpreted as a Unicode string and decoded twice, leading to improper memory allocation and a heap-based buffer overflow.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 8.08% 0.941
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 9.3 8.6 10
AV:N/AC:M/Au:N/C:C/I:C/A:C
CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer

The product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary. This may result in read or write operations on unexpected memory locations that could be linked to other variables, data structures, or internal program data.

http://research.eeye.com/html/advisories/published/AD20071120.html
http://secunia.com/advisories/27717
Patch
Vendor Advisory
http://securityreason.com/securityalert/3405
http://securitytracker.com/id?1018986
http://www.securityfocus.com/archive/1/483986/100/100/threaded
http://www.vupen.com/english/advisories/2007/3935
https://www.exploit-db.com/exploits/4663