Schneider-electric

Modicon M580 Bmeh582040s Firmware

7 Schwachstellen gefunden.

Hinweis: Diese Liste kann unvollständig sein. Daten werden ohne Gewähr im Ursprungsformat bereitgestellt.
  • EPSS 0.16%
  • Veröffentlicht 14.02.2024 17:15:11
  • Zuletzt bearbeitet 23.01.2025 19:39:42

CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle att...

  • EPSS 0.18%
  • Veröffentlicht 01.02.2023 04:15:08
  • Zuletzt bearbeitet 21.11.2024 05:50:39

A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP...

  • EPSS 0.06%
  • Veröffentlicht 31.01.2023 06:15:07
  • Zuletzt bearbeitet 21.11.2024 07:29:43

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All V...

  • EPSS 0.29%
  • Veröffentlicht 30.01.2023 13:15:09
  • Zuletzt bearbeitet 21.11.2024 07:29:43

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is loaded onto the controller. Aff...

  • EPSS 0.33%
  • Veröffentlicht 22.11.2022 12:15:09
  • Zuletzt bearbeitet 21.11.2024 07:14:42

A CWE-191: Integer Underflow (Wrap or Wraparound) vulnerability exists that could cause a denial of service of the controller due to memory access violations when using the Modbus TCP protocol. Affected products: Modicon M340 CPU (part numbers BMXP34...

  • EPSS 0.54%
  • Veröffentlicht 12.09.2022 18:15:08
  • Zuletzt bearbeitet 21.11.2024 07:14:42

A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Includ...

  • EPSS 0.12%
  • Veröffentlicht 14.07.2021 15:15:08
  • Zuletzt bearbeitet 21.11.2024 05:50:38

Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all...