Schneider-electric

Modicon M241 Firmware

8 vulnerabilities found.

Hinweis: Diese Liste kann unvollständig sein. Daten werden ohne Gewähr im Ursprungsformat bereitgestellt.
  • EPSS 0.35%
  • Published 11.07.2024 09:15:04
  • Last modified 21.11.2024 09:49:48

CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting condition where attackers can have a victim’s browser run arbitrary J...

  • EPSS 0.55%
  • Published 26.05.2021 20:15:08
  • Last modified 21.11.2024 05:50:29

Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP.

  • EPSS 0.22%
  • Published 22.04.2020 19:15:11
  • Last modified 21.11.2024 05:37:14

A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers.

  • EPSS 0.19%
  • Published 22.04.2020 19:15:11
  • Last modified 21.11.2024 05:37:14

A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers.

  • EPSS 0.38%
  • Published 22.05.2019 20:29:02
  • Last modified 21.11.2024 04:47:13

A CWE-306: Missing Authentication for Critical Function vulnerability exists which could cause a modification of device IP configuration (IP address, network mask and gateway IP address) when a specific Ethernet frame is received in all versions of: ...

Exploit
  • EPSS 14.76%
  • Published 30.06.2017 03:29:00
  • Last modified 20.04.2025 01:37:25

A Use of Insufficiently Random Values issue was discovered in Schneider Electric Modicon PLCs Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The session numbers generated by t...

  • EPSS 0.23%
  • Published 30.06.2017 03:29:00
  • Last modified 20.04.2025 01:37:25

An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving th...

  • EPSS 0.39%
  • Published 30.06.2017 03:29:00
  • Last modified 20.04.2025 01:37:25

A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware ver...