CVE-2024-2891
- EPSS 0.49%
- Veröffentlicht 26.03.2024 14:15:09
- Zuletzt bearbeitet 22.01.2025 17:51:29
A vulnerability, which was classified as critical, was found in Tenda AC7 15.03.06.44. Affected is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads to stack-based buffer overflow. It is ...
CVE-2023-41562
- EPSS 0.12%
- Veröffentlicht 30.08.2023 13:15:14
- Zuletzt bearbeitet 21.11.2024 08:21:18
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 US_AC5V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter time at url /goform/PowerSaveSet.
CVE-2023-41559
- EPSS 0.16%
- Veröffentlicht 30.08.2023 13:15:14
- Zuletzt bearbeitet 21.11.2024 08:21:17
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter page at url /goform/NatStaticSetting.
CVE-2023-41558
- EPSS 0.12%
- Veröffentlicht 30.08.2023 13:15:14
- Zuletzt bearbeitet 21.11.2024 08:21:17
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter timeZone at url /goform/SetSysTimeCfg.
CVE-2023-41557
- EPSS 0.12%
- Veröffentlicht 30.08.2023 13:15:14
- Zuletzt bearbeitet 21.11.2024 08:21:17
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter entrys and mitInterface at url /goform/addressNat.
CVE-2023-41556
- EPSS 0.14%
- Veröffentlicht 30.08.2023 13:15:13
- Zuletzt bearbeitet 21.11.2024 08:21:17
Tenda AC7 V1.0 V15.03.06.44, Tenda AC9 V3.0 V15.03.06.42_multi, and Tenda AC5 V1.0RTL_V15.03.06.28 were discovered to contain a stack overflow via parameter list at url /goform/SetIpMacBind.
CVE-2023-41555
- EPSS 0.12%
- Veröffentlicht 30.08.2023 13:15:13
- Zuletzt bearbeitet 21.11.2024 08:21:17
Tenda AC7 V1.0 V15.03.06.44 was discovered to contain a stack overflow via parameter security_5g at url /goform/WifiBasicSet.
CVE-2023-41552
- EPSS 0.12%
- Veröffentlicht 30.08.2023 13:15:13
- Zuletzt bearbeitet 21.11.2024 08:21:16
Tenda AC7 V1.0 V15.03.06.44 and Tenda AC9 V3.0 V15.03.06.42_multi were discovered to contain a stack overflow via parameter ssid at url /goform/fast_setting_wifi_set.
CVE-2023-38933
- EPSS 0.12%
- Veröffentlicht 07.08.2023 19:15:11
- Zuletzt bearbeitet 21.11.2024 08:14:28
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSet...
CVE-2023-38936
- EPSS 0.33%
- Veröffentlicht 07.08.2023 19:15:11
- Zuletzt bearbeitet 21.11.2024 08:14:28
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_di...