CVE-2019-10929
- EPSS 0.14%
- Published 13.08.2019 19:15:14
- Last modified 21.11.2024 04:20:10
A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20....
CVE-2013-0700
- EPSS 0.34%
- Published 22.04.2013 03:27:13
- Last modified 11.04.2025 00:51:21
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).
CVE-2013-2780
- EPSS 0.34%
- Published 22.04.2013 03:27:13
- Last modified 11.04.2025 00:51:21
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
CVE-2012-3040
- EPSS 1.21%
- Published 10.10.2012 18:55:02
- Last modified 11.04.2025 00:51:21
Cross-site scripting (XSS) vulnerability in the web server on Siemens SIMATIC S7-1200 PLCs 2.x through 3.0.1 allows remote attackers to inject arbitrary web script or HTML via a crafted URI.
CVE-2012-3037
- EPSS 0.64%
- Published 25.09.2012 11:07:46
- Last modified 11.04.2025 00:51:21
The Siemens SIMATIC S7-1200 2.x PLC does not properly protect the private key of the SIMATIC CONTROLLER Certification Authority certificate, which allows remote attackers to spoof the S7-1200 web server by using this key to create a forged certificat...