6.5
CVE-2026-9297
- EPSS 1.4%
- Veröffentlicht 23.05.2026 10:15:09
- Zuletzt bearbeitet 26.05.2026 19:37:00
- Quelle cna@vuldb.com
- CVE-Watchlists
- Unerledigt
Edimax BR-6428NS POST Request formWlbasic command injection
A security vulnerability has been detected in Edimax BR-6428NS 1.10. Affected is the function formWlbasic of the file /goform/formWlbasic of the component POST Request Handler. The manipulation of the argument repeaterSSID leads to command injection. The attack may be initiated remotely. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Daten sind bereitgestellt durch das CVE Programm von einer CVE Numbering Authority (CNA) (Unstrukturiert).
HerstellerEdimax
≫
Produkt
BR-6428NS
Version
1.10
Status
affected
VulnDex Vulnerability Enrichment
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 1.4% | 0.689 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| cna@vuldb.com | 6.3 | 2.8 | 3.4 |
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L
|
| cna@vuldb.com | 2.1 | 0 | 0 |
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
|
| cna@vuldb.com | 6.5 | 8 | 6.4 |
AV:N/AC:L/Au:S/C:P/I:P/A:P
|
CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')
The product constructs all or part of a command, data structure, or record using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify how it is parsed or interpreted when it is sent to a downstream component.
CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.
https://vuldb.com/vuln/365244
https://vuldb.com/vuln/365244/cti
https://vuldb.com/submit/811536
https://lavender-bicycle-a5a.notion.site/EDIMAX-BR-6428NS-formWlbasic-34b53a41781f807fb398dbab03bdbb38?source=copy_link