6.3
CVE-2026-9143
- EPSS 0.18%
- Veröffentlicht 19.06.2026 13:48:44
- Zuletzt bearbeitet 25.06.2026 14:39:11
- Quelle security@ni.com
- CVE-Watchlists
- Unerledigt
Incorrect Conversion between Numeric Types in NI grpc-device due to missing range checks in CodeGen
There is an incorrect conversion between numeric types vulnerability in NI grpc-device due to missing range checks in CodeGen. This may silently discard high bits if a size value exceeded the target type's range. This affects NI grpc-device 2.17.0 and prior versions.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Ni ≫ Instrumentstudio Version <= 2025
Ni ≫ Instrumentstudio Version2026 Updateq1
Ni ≫ Instrumentstudio Version2026 Updateq2
Ni ≫ Ni Grpc Device Server Version < 2.18.0
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 0.18% | 0.078 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 5.3 | 3.9 | 1.4 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N
|
| security@ni.com | 6.3 | 0 | 0 |
CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
|
| security@ni.com | 3.7 | 2.2 | 1.4 |
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N
|
CWE-681 Incorrect Conversion between Numeric Types
When converting from one data type to another, such as long to integer, data can be omitted or translated in a way that produces unexpected values. If the resulting values are used in a sensitive context, then dangerous behaviors may occur.
https://www.ni.com/en/support/security/available-critical-and-security-updates-for-ni-software/2026/multiple-vulnerabilities-in-ni-grpc-device-server.html
https://github.com/ni/grpc-device/security/advisories/GHSA-rhh6-fvjv-8m84