5.3

CVE-2026-75029

Medienbericht

Message parser retains every identical singleton RDATA, enabling wire-to-work amplification

In a query response, an attacker may send `named` multiple copies of a record that should only exist once (such as an SOA record). If the RDATA is the same on all the copies, the record is appended to the in-memory RDATA set, which can cause increased memory usage of the negative cache and possibly lead to other memory attack vectors.
This issue affects BIND 9 versions 9.11.0 through 9.18.50, 9.20.0 through 9.20.27, 9.21.0 through 9.21.25, 9.11.3-S1 through 9.18.50-S1, and 9.20.9-S1 through 9.20.27-S1.
Daten sind bereitgestellt durch das CVE Programm von einer CVE Numbering Authority (CNA) (Unstrukturiert).
HerstellerISC
≫
Produkt BIND 9
Default Statusunaffected
Version <= 9.18.50
Version 9.11.0
Status affected
Version <= 9.20.27
Version 9.20.0
Status affected
Version <= 9.21.25
Version 9.21.0
Status affected
Version <= 9.18.50-S1
Version 9.11.3-S1
Status affected
Version <= 9.20.27-S1
Version 9.20.9-S1
Status affected
VulnDex Vulnerability Enrichment
Diese Information steht angemeldeten Benutzern zur Verfügung. Login Login
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.41% 0.345
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
ISC 5.3 3.9 1.4
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
CWE-405 Asymmetric Resource Consumption (Amplification)

The product does not properly control situations in which an adversary can cause the product to consume or produce excessive resources without requiring the adversary to invest equivalent work or otherwise prove authorization, i.e., the adversary's influence is "asymmetric."

Für Zugriff zu Vulnerability Intelligence ist ein VulnDex Zugang erforderlich.
VulnDex Intel
Media Report
17.09.2026 15:48
https://downloads.isc.org/isc/bind9/9.20.29
https://downloads.isc.org/isc/bind9/9.21.26
https://kb.isc.org/docs/cve-2026-75029