8.4

CVE-2026-72895

A vulnerability has been identified in SIMATIC IPC BX-21A (All versions < V31.01.13), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G (All versions < V28.01.15). A BIOS vendor test key is present in the UEFI Secure Boot key database. This could allow a local attacker with physical or administrative access to the device to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled, potentially leading to a full loss of confidentiality, integrity, and availability of the device.
Daten sind bereitgestellt durch das CVE Programm von einer CVE Numbering Authority (CNA) (Unstrukturiert).
HerstellerSiemens
≫
Produkt SIMATIC IPC BX-21A
Default Statusunknown
Version 0
Version < V31.01.13
Status affected
HerstellerSiemens
≫
Produkt SIMATIC IPC RW-543A
Default Statusunknown
Version 0
Version < V1.1.4
Status affected
HerstellerSiemens
≫
Produkt SIMATIC IPC227G / IPC277G / IPC277G PRO / IPC327G / IPC377G
Default Statusunknown
Version 0
Version < V28.01.15
Status affected
VulnDex Vulnerability Enrichment
Diese Information steht angemeldeten Benutzern zur Verfügung. Login Login
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.14% 0.031
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
Siemens 8.4 0 0
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Siemens 7.7 1 6
CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
CWE-1394 Use of Default Cryptographic Key

The product uses a default cryptographic key for potentially critical functionality.

https://cert-portal.siemens.com/productcert/html/ssa-159454.html