Incomplete domain name sanitization during
An attacker can send a notify request that causes a new secondary domain to be added to the bind backend, but causes said backend to update its configuration to an invalid one, leading to the backend no longer able to run on the next restart, requiring manual operation to fix it.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Powerdns ≫ Authoritative Version >= 4.9.0 < 4.9.14
Powerdns ≫ Authoritative Version >= 5.0.0 < 5.0.4
VulnDex Vulnerability Enrichment
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 0.01% | 0.006 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 9.8 | 3.9 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
|
| security@open-xchange.com | 7.4 | 2.2 | 5.2 |
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:H/A:H
|
CWE-94 Improper Control of Generation of Code ('Code Injection')
The product constructs all or part of a code segment using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the syntax or behavior of the intended code segment.