9.8

CVE-2026-1949

Incorrect calculation of buffer size on the stack in AS320T

Delta Electronics AS320T has incorrect calculation of the buffer size on the stack in the GET/PUT request handler of the web service.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
DeltawwAs320t Firmware Version < 1.16
   DeltawwAs320t Version-
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.61% 0.445
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
759f5e80-c8e1-4224-bead-956d7b33c98b 9.8 3.9 5.9
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CWE-131 Incorrect Calculation of Buffer Size

The product does not correctly calculate the size to be used when allocating a buffer, which could lead to a buffer overflow.

https://filecenter.deltaww.com/news/download/doc/Delta-PCSA-2026-00006_AS320T%20Multiple%20vulnerabilities%20(CVE-2026-1949,%201950,%201951,%201952).pdf