8.6

CVE-2026-111560

Media report

OS Command Injection in Barracuda Appliances

Improper neutralization of shell metacharacters in the timezone configuration field in certain Barracuda appliance products using common Barracuda code allows an authenticated administrator to inject OS commands that execute with root privileges when the crafted timezone value is subsequently processed.
Data is provided by the CVE programme from a CVE Numbering Authority (CNA) (unstructured).
VendorBarracuda Networks
≫
Product Barracuda Email Security Gateway (ESG)
Default Statusunaffected
Version <= 9.4.0.27
Version 0
Status affected
VendorBarracuda Networks
≫
Product Barracuda Load Balancer Application Delivery Controller (ADC)
Default Statusunaffected
Version <= 6.4.0
Version 0
Status affected
VendorBarracuda Networks
≫
Product Barracuda Web Application Firewall (WAF)
Default Statusunaffected
Version <= 11.0.1
Version 0
Status affected
VendorBarracuda Networks
≫
Product Barracuda Web Security Gateway (WSG)
Default Statusunaffected
Version <= 16.1.100.100
Version 0
Status affected
VendorBarracuda Networks
≫
Product Barracuda Message Archiver (BMA)
Default Statusunaffected
Version <= 5.5.4.0
Version 0
Status affected
VendorBarracuda Networks
≫
Product Barracuda WAF Control Center (WCC)
Default Statusunaffected
Version <= 2.2.1
Version 0
Status affected
No warning was found for this CVE.
EPSS Metrics
Type Source Score Percentile
EPSS FIRST.org 0.47% 0.408
CVSS Metrics
Source Base Score Exploit Score Impact Score Vector string
mandiant-cve@google.com 8.6 0 0
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.

A VulnDex account is required to access Vulnerability Intelligence.
VulnDex Intel
Media Report
06.11.2026 08:16
A VulnDex account is required to access Vulnerability Intelligence.
VulnDex Intel
Media Report
04.11.2026 10:56
A VulnDex account is required to access Vulnerability Intelligence.
VulnDex Intel
Media Report
03.11.2026 18:31
A VulnDex account is required to access Vulnerability Intelligence.
VulnDex Intel
Media Report
03.11.2026 16:31
https://github.com/mandiant/Vulnerability-Disclosures/blob/master/2026/MNDT-2026-0041.md
https://trust.barracuda.com/security/pre-authentication-authorization-bypass-command-injection