8.6
CVE-2025-66052
- EPSS 0.27%
- Veröffentlicht 09.01.2026 11:54:16
- Zuletzt bearbeitet 14.01.2026 17:50:09
- Quelle cvd@cert.pl
- CVE-Watchlists
- Unerledigt
Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter "system_ntpIt" used by "/cgi-bin/admin/setparam.cgi" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, The vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Vivotek ≫ Ip7137 Firmware Version0200a
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 0.27% | 0.499 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 7.2 | 1.2 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
|
| cvd@cert.pl | 8.6 | 0 | 0 |
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
|
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')