6.9

CVE-2025-40594

A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions), SINAMICS S210 V6.4 (All versions < V6.4 HF2). The affected devices allow a factory reset to be executed without the required privileges due to improper privilege management as well as manipulation of configuration data because of leaked privileges of previous sessions. This could allow an unauthorized attacker to escalate their privileges.

Verknüpft mit AI von unstrukturierten Daten zu bestehenden CPE der NVD
This information is available to logged-in users.
Daten sind bereitgestellt durch das CVE Programm von einer CVE Numbering Authority (CNA) (Unstrukturiert).
VendorSiemens
Product SINAMICS G220 V6.4
Default Statusunknown
Version < V6.4 HF2
Version 0
Status affected
VendorSiemens
Product SINAMICS S200 V6.4
Default Statusunknown
Version < *
Version 0
Status affected
VendorSiemens
Product SINAMICS S210 V6.4
Default Statusunknown
Version < V6.4 HF2
Version 0
Status affected
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 0.01% 0.017
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
productcert@siemens.com 6.3 1 4.7
CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:L
productcert@siemens.com 6.9 0 0
CVSS:4.0/AV:L/AC:H/AT:P/PR:N/UI:A/VC:N/VI:H/VA:L/SC:N/SI:H/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CWE-269 Improper Privilege Management

The product does not properly assign, modify, track, or check privileges for an actor, creating an unintended sphere of control for that actor.