8.5
CVE-2025-40582
- EPSS 0.04%
- Published 13.05.2025 09:39:10
- Last modified 30.05.2025 17:07:00
- Source productcert@siemens.com
- Teams watchlist Login
- Open Login
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions with SINEMA Remote Connect Edge Client installed). Affected devices do not properly sanitize configuration parameters. This could allow a non-privileged local attacker to execute root commands on the device.
Verknüpft mit AI von unstrukturierten Daten zu bestehenden CPE der NVD
This information is available to logged-in users. Login
Data is provided by the National Vulnerability Database (NVD)
Siemens ≫ Scalance Lpe9403 Firmware Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.04% | 0.106 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
productcert@siemens.com | 7.8 | 1.8 | 5.9 |
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
|
productcert@siemens.com | 8.5 | 0 | 0 |
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
|
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.