6.5
CVE-2025-32881
- EPSS 0.16%
- Veröffentlicht 01.05.2025 00:00:00
- Zuletzt bearbeitet 20.06.2025 16:53:44
- CVE-Watchlists
- Unerledigt
An issue was discovered on goTenna v1 devices with app 5.5.3 and firmware 0.25.5. By default, the GID is the user's phone number unless they specifically opt out. A phone number is very sensitive information because it can be tied back to individuals. The app does not encrypt the GID in messages.
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 0.16% | 0.053 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| NIST | 6.5 | 2.8 | 3.6 |
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
|
| MITRE | 4.3 | 2.8 | 1.4 |
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
|
CWE-319 Cleartext Transmission of Sensitive Information
The product transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors.
https://gotenna.com
https://github.com/Dollarhyde/goTenna_v1_and_Mesh_vulnerabilities