9
CVE-2025-30042
- EPSS 0.03%
- Veröffentlicht 02.03.2026 11:14:46
- Zuletzt bearbeitet 09.03.2026 16:49:58
- Quelle cvd@cert.pl
- CVE-Watchlists
- Unerledigt
The CGM CLININET system provides smart card authentication; however, authentication is conducted locally on the client device, and, in reality, only the certificate number is used for access verification. As a result, possession of the certificate number alone is sufficient for authentication, regardless of the actual presence of the smart card or ownership of the private key.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 0.03% | 0.074 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 7.8 | 1.8 | 5.9 |
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
|
| cvd@cert.pl | 9 | 0 | 0 |
CVSS:4.0/AV:A/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
|
CWE-603 Use of Client-Side Authentication
A client/server product performs authentication within client code but not in server code, allowing server-side authentication to be bypassed via a modified client that omits the authentication check.