4.7
CVE-2025-26787
- EPSS 0.04%
- Veröffentlicht 22.12.2025 00:00:00
- Zuletzt bearbeitet 05.01.2026 17:48:54
- Quelle cve@mitre.org
- CVE-Watchlists
- Unerledigt
An error in the SignServer container startup logic was found in Keyfactor SignServer versions prior to 7.2. The Admin CLI command used to configure Certificate access to the initial startup of the container sets a property of "allowany" to allow any user with a valid and trusted client auth certificate to connect. Admins can then set more restricted access to specific certificates. A logic error caused this admin CLI command to be run on each restart of the container instead of only the first startup as intended resetting the configuration to "allowany".
Verknüpft mit AI von unstrukturierten Daten zu bestehenden CPE der NVD
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Keyfactor ≫ Signserver Version < 7.2
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 0.04% | 0.111 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| 134c704f-9b21-4f2e-91b3-4a467353bcc0 | 4.7 | 1.2 | 3.4 |
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
|
CWE-642 External Control of Critical State Data
The product stores security-critical state information about its users, or the product itself, in a location that is accessible to unauthorized actors.