7.8

CVE-2025-24059

Windows Common Log File System Driver Elevation of Privilege Vulnerability

Incorrect conversion between numeric types in Windows Common Log File System Driver allows an authorized attacker to elevate privileges locally.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Microsoft ≫ Windows 10 1507 Version < 10.0.10240.20947
Microsoft ≫ Windows 10 1607 HwPlatform x64 Version < 10.0.14393.7876
Microsoft ≫ Windows 10 1607 HwPlatform x86 Version < 10.0.14393.7876
Microsoft ≫ Windows 10 1809 HwPlatform x64 Version < 10.0.17763.7009
Microsoft ≫ Windows 10 1809 HwPlatform x86 Version < 10.0.17763.7009
Microsoft ≫ Windows 10 21h2 Version < 10.0.19044.5608
Microsoft ≫ Windows 10 22h2 Version < 10.0.19045.5608
Microsoft ≫ Windows 11 22h2 Version < 10.0.22621.5039
Microsoft ≫ Windows 11 23h2 Version < 10.0.22631.5039
Microsoft ≫ Windows 11 24h2 Version < 10.0.26100.3403
Microsoft ≫ Windows 11 24h2 Version > 10.0.26100.3403 < 10.0.26100.3476
Microsoft ≫ Windows Server 2008 Version - Update sp2 HwPlatform x64
Microsoft ≫ Windows Server 2008 Version - Update sp2 HwPlatform x86
Microsoft ≫ Windows Server 2008 Version r2 Update sp1 HwPlatform x64
Microsoft ≫ Windows Server 2012 Version < 6.2.9200.25368
Microsoft ≫ Windows Server 2016 Version < 10.0.14393.7876
Microsoft ≫ Windows Server 2019 Version < 10.0.17763.7009
Microsoft ≫ Windows Server 2022 Version < 10.0.20348.3270
Microsoft ≫ Windows Server 2022 Version > 10.0.20348.3270 < 10.0.20348.3328
Microsoft ≫ Windows Server 2022 23h2 Version < 10.0.25398.1486
Microsoft ≫ Windows Server 2025 Version < 10.0.26100.3403
Microsoft ≫ Windows Server 2025 Version > 10.0.26100.3403 < 10.0.26100.3476
VulnDex Vulnerability Enrichment
Diese Information steht angemeldeten Benutzern zur Verfügung. Login Login
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.53% 0.421
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
Microsoft 7.8 1.8 5.9
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CWE-125 Out-of-bounds Read

The product reads data past the end, or before the beginning, of the intended buffer.

CWE-681 Incorrect Conversion between Numeric Types

When converting from one data type to another, such as long to integer, data can be omitted or translated in a way that produces unexpected values. If the resulting values are used in a sensitive context, then dangerous behaviors may occur.

https://msrc.microsoft.com/update-guide/vulnerability/CVE-2025-24059
Vendor Advisory