7.8
CVE-2025-23402
- EPSS 0.03%
- Published 11.03.2025 09:48:18
- Last modified 23.09.2025 15:28:26
- Source productcert@siemens.com
- Teams watchlist Login
- Open Login
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process.
Verknüpft mit AI von unstrukturierten Daten zu bestehenden CPE der NVD
This information is available to logged-in users. Login
Data is provided by the National Vulnerability Database (NVD)
Siemens ≫ Teamcenter Visualization Version >= 14.0.0 < 14.3.0.13
Siemens ≫ Teamcenter Visualization Version >= 2312.0 < 2312.0009
Siemens ≫ Teamcenter Visualization Version >= 2406.0 < 2406.0007
Siemens ≫ Teamcenter Visualization Version >= 2412.0 < 2412.0002
Siemens ≫ Tecnomatix Plant Simulation Version >= 2302.0 < 2302.0021
Siemens ≫ Tecnomatix Plant Simulation Version >= 2404.0 < 2404.0010
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.03% | 0.062 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
productcert@siemens.com | 7.8 | 1.8 | 5.9 |
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
|
productcert@siemens.com | 7.3 | 0 | 0 |
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
|
CWE-416 Use After Free
The product reuses or references memory after it has been freed. At some point afterward, the memory may be allocated again and saved in another pointer, while the original pointer references a location somewhere within the new allocation. Any operations using the original pointer are no longer valid because the memory "belongs" to the code that operates on the new pointer.