7.8

CVE-2024-53242

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files.
This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)

Verknüpft mit AI von unstrukturierten Daten zu bestehenden CPE der NVD
This information is available to logged-in users.
Data is provided by the National Vulnerability Database (NVD)
SiemensTeamcenter Visualization Version >= 14.2 < 14.2.0.14
SiemensTeamcenter Visualization Version >= 14.3 < 14.3.0.12
SiemensTeamcenter Visualization Version >= 2312.0 < 2312.0008
SiemensTecnomatix Plant Simulation Version >= 2302.0 < 2302.0016
SiemensTecnomatix Plant Simulation Version >= 2404.0 < 2404.0005
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 0.03% 0.067
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
productcert@siemens.com 7.8 1.8 5.9
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
productcert@siemens.com 7.3 0 0
CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CWE-125 Out-of-bounds Read

The product reads data past the end, or before the beginning, of the intended buffer.