9.3
CVE-2024-47562
- EPSS 0.12%
- Published 08.10.2024 09:15:18
- Last modified 11.10.2024 20:04:35
- Source productcert@siemens.com
- Teams watchlist Login
- Open Login
A vulnerability has been identified in Siemens SINEC Security Monitor (All versions < V4.9.0). The affected application does not properly neutralize special elements in user input to the ```ssmctl-client``` command. This could allow an authenticated, lowly privileged local attacker to execute privileged commands in the underlying OS.
Data is provided by the National Vulnerability Database (NVD)
Siemens ≫ Sinec Security Monitor Version < 4.9.0
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.12% | 0.321 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
nvd@nist.gov | 8.8 | 2 | 6 |
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
|
productcert@siemens.com | 9.3 | 0 | 0 |
CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
|
productcert@siemens.com | 8.8 | 2 | 6 |
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
|
CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')
The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.