7.2
CVE-2024-39351
- EPSS 0.66%
- Published 28.06.2024 06:15:05
- Last modified 10.04.2025 18:38:11
- Source security@synology.com
- Teams watchlist Login
- Open Login
A vulnerability regarding improper neutralization of special elements used in an OS command ('OS Command Injection') is found in the NTP configuration. This allows remote authenticated users with administrator privileges to execute arbitrary commands via unspecified vectors. The following models with Synology Camera Firmware versions before 1.0.7-0298 may be affected: BC500 and TC500.
Data is provided by the National Vulnerability Database (NVD)
Synology ≫ Bc500 Firmware Version < 1.0.7-0298
Synology ≫ Tc500 Firmware Version < 1.0.7-0298
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.66% | 0.701 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
nvd@nist.gov | 7.2 | 1.2 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
|
security@synology.com | 7.2 | 1.2 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
|
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.