7.6

CVE-2024-32742

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem.

Verknüpft mit AI von unstrukturierten Daten zu bestehenden CPE der NVD
This information is available to logged-in users.
Data is provided by the National Vulnerability Database (NVD)
SiemensSimatic Cn 4100 Firmware Version < 3.0
   SiemensSimatic Cn 4100 Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 0.14% 0.344
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
productcert@siemens.com 7.6 0.9 6
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
CWE-1326 Missing Immutable Root of Trust in Hardware

A missing immutable root of trust in the hardware results in the ability to bypass secure boot or execute untrusted or adversarial boot code.