A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem.
Verknüpft mit AI von unstrukturierten Daten zu bestehenden CPE der NVD
This information is available to logged-in users. Login
Data is provided by the National Vulnerability Database (NVD)
Siemens ≫ Simatic Cn 4100 Firmware Version < 3.0
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.14% | 0.344 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
productcert@siemens.com | 7.6 | 0.9 | 6 |
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
|
CWE-1326 Missing Immutable Root of Trust in Hardware
A missing immutable root of trust in the hardware results in the ability to bypass secure boot or execute untrusted or adversarial boot code.