7.6

CVE-2024-32742

A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
SiemensSimatic Cn 4100 Firmware Version < 3.0
   SiemensSimatic Cn 4100 Version-
VulnDex Vulnerability Enrichment
Diese Information steht angemeldeten Benutzern zur Verfügung. Login Login
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.14% 0.342
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
productcert@siemens.com 7.6 0.9 6
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
CWE-1326 Missing Immutable Root of Trust in Hardware

A missing immutable root of trust in the hardware results in the ability to bypass secure boot or execute untrusted or adversarial boot code.