6.3

CVE-2024-30208

A vulnerability has been identified in SIMATIC RTLS Locating Manager (6GT2780-0DA00) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-0DA30) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA10) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA20) (All versions < V3.0.1.1), SIMATIC RTLS Locating Manager (6GT2780-1EA30) (All versions < V3.0.1.1). The "DBTest"  tool of SIMATIC RTLS Locating Manager does not properly enforce access restriction. This could allow an authenticated local attacker to extract sensitive information from memory.
Daten sind bereitgestellt durch das CVE Programm von Authorized Data Publishers (ADP) (Unstrukturiert)
Herstellersiemens
Produkt simatic_rtls_locating_manager
Default Statusunknown
Version 0
Version < 3.0.1.1
Status affected
VulnDex Vulnerability Enrichment
Diese Information steht angemeldeten Benutzern zur Verfügung. Login Login
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.05% 0.134
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
productcert@siemens.com 5.2 0 0
CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:L/VI:L/VA:L/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
productcert@siemens.com 6.3 2 3.7
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:L/A:L
CWE-732 Incorrect Permission Assignment for Critical Resource

The product specifies permissions for a security-critical resource in a way that allows that resource to be read or modified by unintended actors.