Dell PowerProtect DD, versions prior to 7.13.0.10, LTS 7.7.5.25, LTS 7.10.1.15, 6.2.1.110 contain an OS command injection vulnerability in the CLI. A local low privileged attacker could potentially exploit this vulnerability, leading to the execution of arbitrary OS commands on the application's underlying OS, with the privileges of the vulnerable application. Exploitation may lead to a system take over by an attacker. 

Data is provided by the National Vulnerability Database (NVD)
DellPowerprotect Data Protection Version < 2.7.6
   DellDp4400 Version-
   DellDp5900 Version-
DellApex Protection Storage Version < 6.2.1.110
   DellDd3300 Version-
   DellDd6400 Version-
   DellDd6900 Version-
   DellDd9400 Version-
   DellDd9900 Version-
DellApex Protection Storage Version >= 7.0 < 7.10.1.15
   DellDd3300 Version-
   DellDd6400 Version-
   DellDd6900 Version-
   DellDd9400 Version-
   DellDd9900 Version-
DellPowerprotect Data Domain SwEditionvirtual Version < 6.2.1.110
   DellDd3300 Version-
   DellDd6400 Version-
   DellDd6900 Version-
   DellDd9400 Version-
   DellDd9900 Version-
DellPowerprotect Data Domain SwEditionvirtual Version >= 7.0 < 7.12.0.0
   DellDd3300 Version-
   DellDd6400 Version-
   DellDd6900 Version-
   DellDd9400 Version-
   DellDd9900 Version-
DellPowerprotect Data Domain Management Center Version < 6.2.1.110
   DellDd3300 Version-
   DellDd6400 Version-
   DellDd6900 Version-
   DellDd9400 Version-
   DellDd9900 Version-
DellPowerprotect Data Domain Management Center Version >= 7.0 < 7.13.0.10
   DellDd3300 Version-
   DellDd6400 Version-
   DellDd6900 Version-
   DellDd9400 Version-
   DellDd9900 Version-
DellEmc Data Domain Os Version < 6.2.1.110
   DellDd3300 Version-
   DellDd6400 Version-
   DellDd6900 Version-
   DellDd9400 Version-
   DellDd9900 Version-
DellEmc Data Domain Os Version >= 7.0 < 7.12.0.0
   DellDd3300 Version-
   DellDd6400 Version-
   DellDd6900 Version-
   DellDd9400 Version-
   DellDd9900 Version-
DellEmc Data Domain Os SwEditionlts2022 Version >= 7.7 < 7.7.5.25
   DellDd3300 Version-
   DellDd6400 Version-
   DellDd6900 Version-
   DellDd9400 Version-
   DellDd9900 Version-
DellEmc Data Domain Os SwEditionlts2023 Version >= 7.10 < 7.10.1.15
   DellDd3300 Version-
   DellDd6400 Version-
   DellDd6900 Version-
   DellDd9400 Version-
   DellDd9900 Version-
DellPowerprotect Data Domain Management Center SwEditionlts2022 Version >= 7.7 < 7.7.5.25
   DellDd3300 Version-
   DellDd6400 Version-
   DellDd6900 Version-
   DellDd9400 Version-
   DellDd9900 Version-
DellPowerprotect Data Domain Management Center SwEditionlts2023 Version >= 7.10 < 7.10.1.15
   DellDd3300 Version-
   DellDd6400 Version-
   DellDd6900 Version-
   DellDd9400 Version-
   DellDd9900 Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 0.07% 0.207
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 7.8 1.8 5.9
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
security_alert@emc.com 7.8 1.8 5.9
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.