9.8

CVE-2023-4291

Frauscher Sensortechnik GmbH FDS101 for FAdC/FAdCi v1.4.24 and all previous versions are vulnerable to a remote code execution (RCE) vulnerability via manipulated parameters of the web interface without authentication. This could lead to a full compromise of the FDS101 device.


Daten sind bereitgestellt durch National Vulnerability Database (NVD)
FrauscherFrauscher Diagnostic System 101 SwPlatformfadc Version <= 1.4.24
FrauscherFrauscher Diagnostic System 101 SwPlatformfadci Version <= 1.4.24
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.72% 0.717
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
info@cert.vde.com 9.8 3.9 5.9
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CWE-94 Improper Control of Generation of Code ('Code Injection')

The product constructs all or part of a code segment using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the syntax or behavior of the intended code segment.