6.8

CVE-2023-4212

​A command injection vulnerability exists in Trane XL824, XL850, XL1050, and Pivot thermostats allowing an attacker to execute arbitrary commands as root using a specially crafted filename. The vulnerability requires physical access to the device via a USB stick.

Daten sind bereitgestellt durch National Vulnerability Database (NVD)
TraneXl824 Firmware Version <= 5.9.8
   TraneXl824 Version-
TraneXl850 Firmware Version <= 5.9.8
   TraneXl850 Version-
TraneXl1050 Firmware Version <= 5.9.8
   TraneXl1050 Version-
TranePivot Firmware Version <= 1.8
   TranePivot Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.09% 0.266
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 6.8 0.9 5.9
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
ics-cert@hq.dhs.gov 6.8 0.9 5.9
CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CWE-74 Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')

The product constructs all or part of a command, data structure, or record using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify how it is parsed or interpreted when it is sent to a downstream component.

CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.