7.5

CVE-2023-39465

Triangle MicroWorks SCADA Data Gateway Use of Hard-coded Cryptograhic Key Information Disclosure Vulnerability. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Triangle MicroWorks SCADA Data Gateway. Authentication is not required to exploit this vulnerability.

The specific flaw exists within the TmwCrypto class. The issue results from the usage of a hard-coded cryptograhic key and the usage of a hard-coded certificate. An attacker can leverage this vulnerability to disclose sensitive information. Was ZDI-CAN-20615.

Verknüpft mit AI von unstrukturierten Daten zu bestehenden CPE der NVD
This information is available to logged-in users.
Data is provided by the National Vulnerability Database (NVD)
TrianglemicroworksScada Data Gateway Version5.1.3.20324
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 0.11% 0.295
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
zdi-disclosures@trendmicro.com 7.5 3.9 3.6
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CWE-321 Use of Hard-coded Cryptographic Key

The use of a hard-coded cryptographic key significantly increases the possibility that encrypted data may be recovered.