8.7
CVE-2023-38380
- EPSS 0.09%
- Published 12.12.2023 12:15:11
- Last modified 21.11.2024 08:13:26
- Source productcert@siemens.com
- Teams watchlist Login
- Open Login
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) (All versions < V3.0.37), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SINAMICS S210 (6SL5...) (All versions >= V6.1 < V6.1 HF2), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) (All versions < V3.0.37). The webserver implementation of the affected products does not correctly release allocated memory after it has been used. An attacker with network access could use this vulnerability to cause a denial-of-service condition in the webserver of the affected product.
Data is provided by the National Vulnerability Database (NVD)
Siemens ≫ 6gk7243-8rx30-0xe0 Firmware Version-
Siemens ≫ 6gk7543-1ax00-0xe0 Firmware Version-
Siemens ≫ 6ag1543-1ax00-2xe0 Firmware Version-
Siemens ≫ Simatic Cp 1242-7 V2 Firmware Version-
Siemens ≫ Simatic Cp 1243-1 Firmware Version-
Siemens ≫ Simatic Cp 1243-1 Dnp3 Firmware Version-
Siemens ≫ Simatic Cp 1243-1 Iec Firmware Version-
Siemens ≫ Sinamics S210 Firmware Version5.1 Update-
Siemens ≫ Sinamics S210 Firmware Version5.1 Updatesp1
Siemens ≫ Sinamics S210 Firmware Version5.1 Updatesp1_hotfix8
Siemens ≫ Sinamics S210 Firmware Version5.2 Update-
Siemens ≫ Sinamics S210 Firmware Version5.2 Updatehotfix2
Siemens ≫ Sinamics S210 Firmware Version5.2 Updatehotfix5
Siemens ≫ Sinamics S210 Firmware Version5.2 Updatehotfix6
Siemens ≫ Sinamics S210 Firmware Version5.2 Updatehotfix7
Siemens ≫ Sinamics S210 Firmware Version5.2 Updatesp3
Siemens ≫ Sinamics S210 Firmware Version5.2 Updatesp3_hotfix3
Siemens ≫ Sinamics S210 Firmware Version5.2 Updatesp3_hotfix5
Siemens ≫ Sinamics S210 Firmware Version5.2 Updatesp3_hotfix6
Siemens ≫ Sinamics S210 Firmware Version5.2 Updatesp3_hotfix9
Siemens ≫ Sinamics S210 Firmware Version6.1 Update-
Siemens ≫ Sinamics S210 Firmware Version6.1 Updatehotfix1
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.09% | 0.259 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
productcert@siemens.com | 8.7 | 0 | 0 |
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
|
productcert@siemens.com | 7.5 | 3.9 | 3.6 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
|
CWE-401 Missing Release of Memory after Effective Lifetime
The product does not sufficiently track and release allocated memory after it has been used, which slowly consumes remaining memory.