4.4

CVE-2023-37195

A vulnerability has been identified in SIMATIC CP 1604 (All versions), SIMATIC CP 1616 (All versions), SIMATIC CP 1623 (All versions), SIMATIC CP 1626 (All versions), SIMATIC CP 1628 (All versions). Affected devices insufficiently control continuous mapping of direct memory access (DMA) requests. This could allow local attackers with administrative privileges to cause a denial of service situation on the host. A physical power cycle is required to get the system working again.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Siemens ≫ Simatic Cp 1604 Firmware Version -
   Siemens ≫ Simatic Cp 1604 Version -
Siemens ≫ Simatic Cp 1616 Firmware Version -
   Siemens ≫ Simatic Cp 1616 Version -
Siemens ≫ Simatic Cp 1623 Firmware Version -
   Siemens ≫ Simatic Cp 1623 Version -
Siemens ≫ Simatic Cp 1626 Firmware Version -
   Siemens ≫ Simatic Cp 1626 Version -
Siemens ≫ Simatic Cp 1628 Firmware Version -
   Siemens ≫ Simatic Cp 1628 Version -
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.16% 0.058
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
Siemens 4.4 0.8 3.6
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H
CWE-400 Uncontrolled Resource Consumption

The product does not properly control the allocation and maintenance of a limited resource.

https://cert-portal.siemens.com/productcert/pdf/ssa-784849.pdf
Vendor Advisory