7.4

CVE-2023-31174

A Cross-Site Request Forgery (CSRF) vulnerability in the Schweitzer Engineering Laboratories SEL-5037 SEL Grid Configurator could allow an attacker to embed instructions that could be executed by an authorized device operator.





See Instruction Manual Appendix A and Appendix E dated 20230615 for more details.


This issue affects SEL-5037 SEL Grid Configurator: before 4.5.0.20.

Daten sind bereitgestellt durch National Vulnerability Database (NVD)
SelincSel-5037 Sel Grid Configurator Version < 4.5.0.20
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.05% 0.142
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 6.5 2.8 3.6
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N
security@selinc.com 7.4 2.8 4
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:N
CWE-352 Cross-Site Request Forgery (CSRF)

The web application does not, or can not, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the request.