7.2

CVE-2023-28832

A vulnerability has been identified in SIMATIC Cloud Connect 7 CC712 (All versions >= V2.0 < V2.1), SIMATIC Cloud Connect 7 CC716 (All versions >= V2.0 < V2.1). The web based management of affected devices does not properly validate user input, making it susceptible to command injection. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.

Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Siemens6gk1411-1ac00 Firmware Version2.0
   Siemens6gk1411-1ac00 Version-
Siemens6gk1411-5ac00 Firmware Version2.0
   Siemens6gk1411-5ac00 Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.79% 0.726
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
productcert@siemens.com 7.2 1.2 5.9
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')

The product constructs all or part of a command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended command when it is sent to a downstream component.