8.8

CVE-2023-20038

A vulnerability in the monitoring application of Cisco Industrial Network Director could allow an authenticated, local attacker to access a static secret key used to store both local data and credentials for accessing remote systems.

 This vulnerability is due to a static key value stored in the application used to encrypt application data and remote credentials. An attacker could exploit this vulnerability by gaining local access to the server Cisco Industrial Network Director is installed on. A successful exploit could allow the attacker to decrypt data allowing the attacker to access remote systems monitored by Cisco Industrial Network Director.

Data is provided by the National Vulnerability Database (NVD)
CiscoIndustrial Network Director Version < 1.6.0
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 0.05% 0.105
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 8.8 2 6
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
psirt@cisco.com 8.8 2 6
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
CWE-321 Use of Hard-coded Cryptographic Key

The use of a hard-coded cryptographic key significantly increases the possibility that encrypted data may be recovered.

CWE-798 Use of Hard-coded Credentials

The product contains hard-coded credentials, such as a password or cryptographic key.