9.8

CVE-2022-37130

Exploit

In D-Link DIR-816 A2_v1.10CNB04, DIR-878 DIR_878_FW1.30B08.img a command injection vulnerability occurs in /goform/Diagnosis, after the condition is met, setnum will be spliced into v10 by snprintf, and the system will be executed, resulting in a command injection vulnerability

Data is provided by the National Vulnerability Database (NVD)
DlinkDir-816 Firmware Version1.10cnb04
   DlinkDir-816 Versiona2
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 41.26% 0.973
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 9.8 3.9 5.9
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.