9.8
CVE-2022-33186
- EPSS 1.24%
- Veröffentlicht 08.12.2022 22:15:10
- Zuletzt bearbeitet 23.04.2025 16:15:20
- Quelle sirt@brocade.com
- CVE-Watchlists
- Unerledigt
A vulnerability in Brocade Fabric OS software v9.1.1, v9.0.1e, v8.2.3c, v7.4.2j, and earlier versions could allow a remote unauthenticated attacker to execute on a Brocade Fabric OS switch commands capable of modifying zoning, disabling the switch, disabling ports, and modifying the switch IP address.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Brocade ≫ Fabric Operating System Version7.4.2j
Brocade ≫ Fabric Operating System Version8.2.3c
Brocade ≫ Fabric Operating System Version9.0.1e
Brocade ≫ Fabric Operating System Version9.1.1
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 1.24% | 0.786 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 9.8 | 3.9 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
|
| 134c704f-9b21-4f2e-91b3-4a467353bcc0 | 9.8 | 3.9 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
|
CWE-78 Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
The product constructs all or part of an OS command using externally-influenced input from an upstream component, but it does not neutralize or incorrectly neutralizes special elements that could modify the intended OS command when it is sent to a downstream component.