7.8
CVE-2022-27194
- EPSS 0.16%
- Veröffentlicht 12.04.2022 09:15:15
- Zuletzt bearbeitet 21.11.2024 06:55:23
- Quelle productcert@siemens.com
- Teams Watchlist Login
- Unerledigt Login
A vulnerability has been identified in SIMATIC PCS neo (Administration Console) (All versions < V3.1 SP1), SINETPLAN (All versions), TIA Portal (V15, V15.1, V16 and V17). The affected system cannot properly process specially crafted packets sent to port 8888/tcp. A remote attacker could exploit this vulnerability to cause a Denial-of-Service condition. The affected devices must be restarted manually.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Siemens ≫ Simatic Pcs Neo Version < 3.1
Siemens ≫ Simatic Pcs Neo Version3.1 Update-
Siemens ≫ Totally Integrated Automation Portal Version15
Siemens ≫ Totally Integrated Automation Portal Version15.1 Update-
Siemens ≫ Totally Integrated Automation Portal Version16
Siemens ≫ Totally Integrated Automation Portal Version17
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Typ | Quelle | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.16% | 0.375 |
Quelle | Base Score | Exploit Score | Impact Score | Vector String |
---|---|---|---|---|
nvd@nist.gov | 7.5 | 3.9 | 3.6 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
|
nvd@nist.gov | 7.8 | 10 | 6.9 |
AV:N/AC:L/Au:N/C:N/I:N/A:C
|
CWE-400 Uncontrolled Resource Consumption
The product does not properly control the allocation and maintenance of a limited resource, thereby enabling an actor to influence the amount of resources consumed, eventually leading to the exhaustion of available resources.