9.8
CVE-2022-2475
- EPSS 0.6%
- Veröffentlicht 28.10.2022 18:15:11
- Zuletzt bearbeitet 21.11.2024 07:01:04
- Quelle ics-cert@hq.dhs.gov
- CVE-Watchlists
- Unerledigt
Haas Controller version 100.20.000.1110 has insufficient granularity of access control when using the "Ethernet Q Commands" service. Any user is able to write macros into registers outside of the authorized accessible range. This could allow a user to access privileged resources or resources out of context.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Haascnc ≫ Haas Controller Firmware Version100.20.000.1110
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 0.6% | 0.438 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 8.8 | 2.8 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
|
| ics-cert@hq.dhs.gov | 9.8 | 3.9 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
|
CWE-1220 Insufficient Granularity of Access Control
The product implements access controls via a policy or other feature with the intention to disable or restrict accesses (reads and/or writes) to assets in a system from untrusted agents. However, implemented access controls lack required granularity, which renders the control policy too broad because it allows accesses from unauthorized agents to the security-sensitive assets.
https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-01