6.5
CVE-2022-2179
- EPSS 0.82%
- Veröffentlicht 20.07.2022 16:15:09
- Zuletzt bearbeitet 21.11.2024 07:00:29
- Quelle ics-cert@hq.dhs.gov
- Teams Watchlist Login
- Unerledigt Login
The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Rockwellautomation ≫ Micrologix 1400 Firmware Version <= 21.007
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Typ | Quelle | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.82% | 0.734 |
Quelle | Base Score | Exploit Score | Impact Score | Vector String |
---|---|---|---|---|
nvd@nist.gov | 6.5 | 2.8 | 3.6 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:N
|
ics-cert@hq.dhs.gov | 6.5 | 2.8 | 3.6 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
|
CWE-1021 Improper Restriction of Rendered UI Layers or Frames
The web application does not restrict or incorrectly restricts frame objects or UI layers that belong to another application or domain, which can lead to user confusion about which interface the user is interacting with.