7.1

CVE-2021-37203

A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The plmxmlAdapterIFC.dll contains an out-of-bounds read while parsing user supplied IFC files which could result in a read past the end of an allocated buffer. This could allow an attacker to cause a denial-of-service condition or read sensitive information from memory locations.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Siemens ≫ Nx 1980 Version < 1984
Siemens ≫ Solid Edge Version < se2021
Siemens ≫ Solid Edge Version se2021 Update -
Siemens ≫ Solid Edge Version se2021 Update maintenance_pack1
Siemens ≫ Solid Edge Version se2021 Update maintenance_pack2
Siemens ≫ Solid Edge Version se2021 Update maintenance_pack3
Siemens ≫ Solid Edge Version se2021 Update maintenance_pack4
Siemens ≫ Solid Edge Version se2021 Update maintenance_pack5
Siemens ≫ Solid Edge Version se2021 Update maintenance_pack6
Siemens ≫ Solid Edge Version se2021 Update maintenance_pack7
Zu dieser CVE wurde keine Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.64% 0.461
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
NIST 7.1 1.8 5.2
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:H
NIST 5.8 8.6 4.9
AV:N/AC:M/Au:N/C:P/I:N/A:P
CWE-125 Out-of-bounds Read

The product reads data past the end, or before the beginning, of the intended buffer.

https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf
Patch
Vendor Advisory
https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf
Patch
Vendor Advisory