Rockwell Automation FactoryTalk Services Platform v6.11 and earlier, if FactoryTalk Security is enabled and deployed contains a vulnerability that may allow a remote, authenticated attacker to bypass FactoryTalk Security policies based on the computer name. If successfully exploited, this may allow an attacker to have the same privileges as if they were logged on to the client machine.
Data is provided by the National Vulnerability Database (NVD)
Rockwellautomation ≫ Factorytalk Services Platform Version <= 6.11.00
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.04% | 0.086 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
nvd@nist.gov | 8.8 | 2.8 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
|
nvd@nist.gov | 6 | 6.8 | 6.4 |
AV:N/AC:M/Au:S/C:P/I:P/A:P
|
ics-cert@hq.dhs.gov | 8.5 | 1.8 | 6 |
CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:H
|
CWE-693 Protection Mechanism Failure
The product does not use or incorrectly uses a protection mechanism that provides sufficient defense against directed attacks against the product.
CWE-863 Incorrect Authorization
The product performs an authorization check when an actor attempts to access a resource or perform an action, but it does not correctly perform the check.