5.3

CVE-2021-32496

SICK Visionary-S CX up version 5.21.2.29154R are vulnerable to an Inadequate Encryption Strength vulnerability concerning the internal SSH interface solely used by SICK for recovering returned devices. The use of weak ciphers make it easier for an attacker to break the security that protects information transmitted from the client to the SSH server, assuming the attacker has access to the network on which the device is connected. This can increase the risk that encryption will be compromised, leading to the exposure of sensitive user information and man-in-the-middle attacks.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
SickVisionary-s Cx Firmware Version < 5.21.2.29154r
   SickVisionary-s Cx Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.07% 0.189
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 5.3 1.6 3.6
CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N
nvd@nist.gov 3.5 6.8 2.9
AV:N/AC:M/Au:S/C:P/I:N/A:N
CWE-326 Inadequate Encryption Strength

The product stores or transmits sensitive data using an encryption scheme that is theoretically sound, but is not strong enough for the level of protection required.