9.1
CVE-2021-31345
- EPSS 1.25%
- Published 09.11.2021 12:15:09
- Last modified 21.11.2024 06:05:27
- Source productcert@siemens.com
- Teams watchlist Login
- Open Login
A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions). The total length of an UDP payload (set in the IP header) is unchecked. This may lead to various side effects, including Information Leak and Denial-of-Service conditions, depending on a user-defined applications that runs on top of the UDP protocol. (FSMD-2021-0006)
Data is provided by the National Vulnerability Database (NVD)
Siemens ≫ Nucleus Readystart V3 Version < 2014.12
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 1.25% | 0.784 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
nvd@nist.gov | 9.1 | 3.9 | 5.2 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H
|
nvd@nist.gov | 6.4 | 10 | 4.9 |
AV:N/AC:L/Au:N/C:P/I:N/A:P
|
productcert@siemens.com | 7.5 | 3.9 | 3.6 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
|
CWE-1284 Improper Validation of Specified Quantity in Input
The product receives input that is expected to specify a quantity (such as size or length), but it does not validate or incorrectly validates that the quantity has the required properties.