8.6

CVE-2021-27475

Rockwell Automation Connected Components Workbench v12.00.00 and prior does not limit the objects that can be deserialized. This vulnerability allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in remote code execution. This vulnerability requires user interaction to be successfully exploited.

Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 0.21% 0.431
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 8.6 1.8 6
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
nvd@nist.gov 6.8 8.6 6.4
AV:N/AC:M/Au:N/C:P/I:P/A:P
ics-cert@hq.dhs.gov 8.6 1.8 6
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
CWE-502 Deserialization of Untrusted Data

The product deserializes untrusted data without sufficiently ensuring that the resulting data will be valid.