9.8

CVE-2021-27384

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). SmartVNC has an out-of-bounds memory access vulnerability in the device layout handler, represented by a binary data stream on client side, which can potentially result in code execution.

Daten sind bereitgestellt durch National Vulnerability Database (NVD)
SiemensSimatic Wincc Runtime Advanced Version16 Update-
SiemensSimatic Wincc Runtime Advanced Version16 Updateupdate1
SiemensSimatic Wincc Runtime Advanced Version16 Updateupdate2
SiemensSimatic Wincc Runtime Advanced Version16 Updateupdate3
SiemensSimatic Hmi Comfort Panels 4" Firmware Version15.1 Updateupdate1
SiemensSimatic Hmi Comfort Panels 4" Firmware Version15.1 Updateupdate2
SiemensSimatic Hmi Comfort Panels 4" Firmware Version15.1 Updateupdate3
SiemensSimatic Hmi Comfort Panels 4" Firmware Version15.1 Updateupdate4
SiemensSimatic Hmi Comfort Panels 4" Firmware Version15.1 Updateupdate5
SiemensSimatic Wincc Runtime Advanced Version15.1 Update-
SiemensSimatic Wincc Runtime Advanced Version15.1 Updateupdate1
SiemensSimatic Wincc Runtime Advanced Version15.1 Updateupdate2
SiemensSimatic Wincc Runtime Advanced Version15.1 Updateupdate3
SiemensSimatic Wincc Runtime Advanced Version15.1 Updateupdate4
SiemensSimatic Wincc Runtime Advanced Version15.1 Updateupdate5
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Typ Quelle Score Percentile
EPSS FIRST.org 1.43% 0.788
CVSS Metriken
Quelle Base Score Exploit Score Impact Score Vector String
nvd@nist.gov 9.8 3.9 5.9
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
nvd@nist.gov 7.5 10 6.4
AV:N/AC:L/Au:N/C:P/I:P/A:P
CWE-788 Access of Memory Location After End of Buffer

The product reads or writes to a buffer using an index or pointer that references a memory location after the end of the buffer.