6.1

CVE-2021-22813

A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause arbritrary script execution when a privileged account clicks on a malicious URL specifically crafted for the NMC pointing to an edit policy file. Affected Products: 1-Phase Uninterruptible Power Supply (UPS) using NMC2 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.8 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 250/500 (SYPX) Network Management Card 2 (NMC2): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635J (NMC2 AOS V6.9.6 and earlier), 3-Phase Uninterruptible Power Supply (UPS) using NMC2 including Symmetra PX 48/96/100/160 kW UPS (PX2), Symmetra PX 20/40 kW UPS (SY3P), Gutor (SXW, GVX), and Galaxy (GVMTS, GVMSA, GVXTS, GVXSA, G7K, GFC, G9KCHU): AP9630/AP9630CH/AP9630J, AP9631/AP9631CH/AP9631J, AP9635/AP9635CH (NMC2 AOS V6.9.6 and earlier), 1-Phase Uninterruptible Power Supply (UPS) using NMC3 including Smart-UPS, Symmetra, and Galaxy 3500 with Network Management Card 3 (NMC3): AP9640/AP9640J, AP9641/AP9641J, AP9643/AP9643J (NMC3 AOS V1.4.2.1 and earlier), APC Rack Power Distribution Units (PDU) using NMC2 2G Metered/Switched Rack PDUs with embedded NMC2: AP84XX, AP86XX, AP88XX, AP89XX (NMC2 AOS V6.9.6 and earlier), APC Rack Power Distribution Units (PDU) using NMC3 2G Metered/Switched Rack PDUs with embedded NMC3: APDU99xx (NMC3 AOS V1.4.0 and earlier), APC 3-Phase Power Distribution Products using NMC2 Galaxy RPP: GRPPIP2X84 (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) for InfraStruxure 150 kVA PDU with 84 Poles (X84P): PDPB150G6F (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for InfraStruxure 40/60kVA PDU (XPDU) PD40G6FK1-M, PD40F6FK1-M, PD40L6FK1-M, PDRPPNX10 M,PD60G6FK1, PD60F6FK1, PD60L6FK1, PDRPPNX10, PD40E5EK20-M, PD40H5EK20-M (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular 150/175kVA PDU (XRDP): PDPM150G6F, PDPM150L6F, PDPM175G6H (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for 400 and 500 kVA (PMM): PMM400-ALA, PMM400-ALAX, PMM400-CUB, PMM500-ALA, PMM500-ALAX, PMM500-CUB (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 for Modular PDU (XRDP2G): PDPM72F-5U, PDPM138H-5U, PDPM144F, PDPM138H-R, PDPM277H, PDPM288G6H (NMC2 AOS V6.9.6 and earlier), Rack Automatic Transfer Switches (ATS) Embedded NMC2: Rack Automatic Transfer Switches - AP44XX (ATS4G) (NMC2 AOS V6.9.6 and earlier), Network Management Card 2 (NMC2) Cooling Products: InRow Cooling for series ACRP5xx, ACRP1xx, ACRD5xx, and ACRC5xx SKUs (ACRP2G), InRow Cooling for series ACRC10x SKUs (RC10X2G), InRow Cooling for series ACRD6xx and ACRC6xx SKUs (ACRD2G), InRow Cooling Display for series ACRD3xx (ACRC2G), InRow Cooling for series ACSC1xx SKUs (SC2G), InRow Cooling for series ACRD1xx and ACRD2xx (ACRPTK2G), Ecoflair IAEC25/50 Air Economizer Display (EB2G), Uniflair SP UCF0481I, UCF0341I (UNFLRSP), Uniflair LE DX Perimeter Cooling Display for SKUs: IDAV, IDEV, IDWV, IUAV, IUEV, IUWV, IXAV, IXEV, IXWV, LDAV, LDEV, and LDWV (LEDX2G), Refrigerant Distribution Unit: ACDA9xx (RDU) (NMC2 AOS V6.9.6 and earlier), Environmental Monitoring Unit with embedded NMC2 (NB250): NetBotz NBRK0250 (NMC2 AOS V6.9.6 and earlier), and Network Management Card 2 (NMC2): AP9922 Battery Management System (BM4) (NMC2 AOS V6.9.6 and earlier)

Data is provided by the National Vulnerability Database (NVD)
Schneider-electricNetwork Management Card 2 Firmware Version <= 6.9.6
   Schneider-electricAp9922 Battery Management System Version-
   Schneider-electricApc Rack Power Distribution Units Version-
   Schneider-electricGalaxy G7x Version-
   Schneider-electricGalaxy G9kchu Version-
   Schneider-electricGalaxy Gcxsa Version-
   Schneider-electricGalaxy Gfc Version-
   Schneider-electricGalaxy Gvmsa Version-
   Schneider-electricGalaxy Gvmts Version-
   Schneider-electricGalaxy Gvxts Version-
   Schneider-electricGalaxy Rpp Grppip2x84 Version-
   Schneider-electricGutor Gvx Version-
   Schneider-electricGutor Sxw Version-
   Schneider-electricNetbotz Nbrk0250 Version-
   Schneider-electricNetwork Management Card 2 Version-
   Schneider-electricPd40e5ek20-m Version-
   Schneider-electricPd40f6fk1-m Version-
   Schneider-electricPd40g6fk1-m Version-
   Schneider-electricPd40h5ek20-m Version-
   Schneider-electricPd40l6fk1-m Version-
   Schneider-electricPd60f6fk1 Version-
   Schneider-electricPd60g6fk1 Version-
   Schneider-electricPd60l6fk1 Version-
   Schneider-electricPdpb150g6f Version-
   Schneider-electricPdpm138h-5u Version-
   Schneider-electricPdpm138h-r Version-
   Schneider-electricPdpm144f Version-
   Schneider-electricPdpm150g6f Version-
   Schneider-electricPdpm150l6f Version-
   Schneider-electricPdpm175g6h Version-
   Schneider-electricPdpm277h Version-
   Schneider-electricPdpm288g6h Version-
   Schneider-electricPdpm72f-5u Version-
   Schneider-electricPdrppnx10 Version-
   Schneider-electricPdrppnx10m Version-
   Schneider-electricPmm400-ala Version-
   Schneider-electricPmm400-alax Version-
   Schneider-electricPmm400-cub Version-
   Schneider-electricPmm500-ala Version-
   Schneider-electricPmm500-alax Version-
   Schneider-electricPmm500-cub Version-
   Schneider-electricRack Automatic Transfer Switches Version-
   Schneider-electricSymmetra Px 100 Version-
   Schneider-electricSymmetra Px 160 Version-
   Schneider-electricSymmetra Px 20 Version-
   Schneider-electricSymmetra Px 250 Version-
   Schneider-electricSymmetra Px 40 Version-
   Schneider-electricSymmetra Px 48 Version-
   Schneider-electricSymmetra Px 500 Version-
   Schneider-electricSymmetra Px 96 Version-
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
EPSS Metriken
Type Source Score Percentile
EPSS FIRST.org 0.82% 0.721
CVSS Metriken
Source Base Score Exploit Score Impact Score Vector string
nvd@nist.gov 6.1 2.8 2.7
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
nvd@nist.gov 4.3 8.6 2.9
AV:N/AC:M/Au:N/C:N/I:P/A:N
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.