10
CVE-2021-22729
- EPSS 0.35%
- Veröffentlicht 21.07.2021 15:15:14
- Zuletzt bearbeitet 21.11.2024 05:50:32
- Quelle cybersecurity@se.com
- CVE-Watchlists
- Unerledigt
A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.
Daten sind bereitgestellt durch National Vulnerability Database (NVD)
Schneider-electric ≫ Evlink City Evc1s22p4 Firmware Version < r8_v3.4.0.1
Schneider-electric ≫ Evlink City Evc1s7p4 Firmware Version < r8_v3.4.0.1
Schneider-electric ≫ Evlink Parking Evw2 Firmware Version < r8_v3.4.0.1
Schneider-electric ≫ Evlink Parking Evf2 Firmware Version < r8_v3.4.0.1
Schneider-electric ≫ Evlink Parking Ev.2 Firmware Version < r8_v3.4.0.1
Schneider-electric ≫ Evlink Smart Wallbox Evb1a Firmware Version < r8_v3.4.0.1
| Typ | Quelle | Score | Percentile |
|---|---|---|---|
| EPSS | FIRST.org | 0.35% | 0.541 |
| Quelle | Base Score | Exploit Score | Impact Score | Vector String |
|---|---|---|---|---|
| nvd@nist.gov | 9.8 | 3.9 | 5.9 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
|
| nvd@nist.gov | 10 | 10 | 10 |
AV:N/AC:L/Au:N/C:C/I:C/A:C
|
CWE-259 Use of Hard-coded Password
The product contains a hard-coded password, which it uses for its own inbound authentication or for outbound communication to external components.