6.1
CVE-2020-7579
- EPSS 0.37%
- Published 10.03.2020 20:15:22
- Last modified 21.11.2024 05:37:24
- Source productcert@siemens.com
- Teams watchlist Login
- Open Login
A vulnerability has been identified in Spectrum Power™ 5 (All versions < v5.50 HF02). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. If deployed according to recommended system configuration, Siemens consideres the environmental vector as CR:L/IR:M/AR:H/MAV:A (4.1).
Data is provided by the National Vulnerability Database (NVD)
Siemens ≫ Spectrum Power 5 Version <= 5.50
Siemens ≫ Spectrum Power 5 Version5.50 Updatehf01
Zu dieser CVE wurde keine CISA KEV oder CERT.AT-Warnung gefunden.
Type | Source | Score | Percentile |
---|---|---|---|
EPSS | FIRST.org | 0.37% | 0.581 |
Source | Base Score | Exploit Score | Impact Score | Vector string |
---|---|---|---|---|
nvd@nist.gov | 6.1 | 2.8 | 2.7 |
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
|
nvd@nist.gov | 4.3 | 8.6 | 2.9 |
AV:N/AC:M/Au:N/C:N/I:P/A:N
|
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
The product does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is served to other users.
CWE-80 Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
The product receives input from an upstream component, but it does not neutralize or incorrectly neutralizes special characters such as "<", ">", and "&" that could be interpreted as web-scripting elements when they are sent to a downstream component that processes web pages.